   源码介绍
上位PC机有控制和读取PLC内部软元件的功能,需要添加三菱MX COMPONENT软件的类引用

Option Strict On
Imports ActUtlTypeLib
Imports ActProgTypeLib
Imports AxActUtlTypeLib

Private Sub Form1_Load(sender As Object, e As EventArgs) Handles MyBase.Load

        mycommunication.ActLogicalStationNumber = 1
        back = mycommunication.Open()
        If back <> 0 Then
            MsgBox("连接失败")
            GroupBox1.Enabled = False
            IOToolStripMenuItem.Enabled = False
        End If
    End Sub
    Private Sub Form1_Closing(sender As Object, e As EventArgs) Handles MyBase.FormClosing
        back = mycommunication.Close()
    End Sub
Private Sub BtnYSET_Click(sender As Object, e As EventArgs) Handles BtnYSET.Click
        Dim a As String = TxtY.Text
        Dim b As Boolean = False
        b = Txt2Number(a, 8)
        If b = True Then
            mycommunication.SetDevice("Y" & TxtY.Text, 1)
            LabelY显示.ForeColor = Color.Lime
        Else
            MsgBox("输入Y编号不正确")
            Exit Sub
        End If
    End Sub
Private Sub BtnDWrite_Click(sender As Object, e As EventArgs) Handles BtnDWrite.Click
        Dim a As String = TxtD.Text

        Dim b As Boolean = False

        Dim writevalue(1) As Int32
        b = Txt2Number(a, 10)

        If b = True Then
            Try
                writevalue(0) = Convert.ToInt32(TxtDValue.Text)
            Catch ex As Exception
                MessageBox.Show(ex.ToString)
            End Try
            If CheckBoxY32.Checked = True Then
                Dim sharrBufferForDeviceValue(1) As Short
                Dim byarrBufferByte() As Byte
                byarrBufferByte = BitConverter.GetBytes(CInt(TxtDValue.Text))
                sharrBufferForDeviceValue(0) = BitConverter.ToInt16(byarrBufferByte, 0)
                sharrBufferForDeviceValue(1) = BitConverter.ToInt16(byarrBufferByte, 2)
                mycommunication.WriteDeviceBlock2("D" & TxtD.Text, 2, sharrBufferForDeviceValue(0))
            Else
                If (writevalue(0) > 32767 OrElse writevalue(0) < -32768) Then
                    MsgBox("输入D数值超出界限")
                Else
                    mycommunication.WriteDeviceBlock("D" & TxtD.Text, 1, writevalue(0))
                End If
            End If
        Else
            MsgBox("输入D编号不正确")
            Exit Sub
        End If
    End Sub
    Private Sub BtnDRead_Click(sender As Object, e As EventArgs) Handles BtnDRead.Click
        Dim a As String = TxtD.Text
        Dim b As Boolean = False
        Dim readvalue(1) As Int32
        b = Txt2Number(a, 10)
        If b = True Then
            If CheckBoxDR32.Checked = True Then
                Dim Value32 As Integer
                Dim bianhao As Integer
                bianhao = Convert.ToInt32(TxtD.Text)
                mycommunication.ReadDeviceBlock("D" & bianhao, 1, readvalue(0))
                mycommunication.ReadDeviceBlock("D" & (bianhao 1), 1, readvalue(1))
                If (readvalue(1) > 32767) Then
                    readvalue(1) = readvalue(1) - 65536
                End If
                Value32 = 65536 * readvalue(1) readvalue(0)
                TxtDRead.Text = Value32.ToString
            Else
                mycommunication.ReadDeviceBlock("D" & TxtD.Text, 1, readvalue(0))
                If (readvalue(0) > 32767) Then
                    TxtDRead.Text = (readvalue(0) - 65536).ToString
                Else
                    TxtDRead.Text = readvalue(0).ToString
                End If
            End If
        Else
            MsgBox("输入D编号不正确")
            Exit Sub
        End If
    End Sub